About this item

  • The proper ods pilot assembly must be used for the correct model number heater.
  • The 120630-01 Pilot ODS assembly take the 120790-01 Dual Wire Thermocouple. The 120790-01 Thermocouple Dual Wire 33 Inch Length with silver and brown transmitter wires that fits the Desa International Unvented Vent-Free infrared gas wall heater.
  • 120630-01 Pilot ODS assembly used on many of the unvented Natural Gas Gas wall heaters and NG unvented gas log sets and fireplaces.
  • Some of the Brand Names were Vanguard, Comfort Flame, Glo-Warm, Cozy Heat, Kozy World, Pro Com, Desa International and others.
  • Many of the Unvented Gas Logs sets, Wall Heaters and fireplaces that used the 120630-01 Pilot ODS were made by DESA International , Compatible With Ace Hardware, Home Depot, Sears, Menards Store Many Brand .



Product Description

120630-01 Pilot ODS Assembly For Vent Free Natural Gas Wall Heaters By DESA, Glo- Warm

120630-01 Pilot ODS assembly

The 120630-01 Pilot ODS assembly was used on many of the unvented Natural Gas Gas wall heaters and NG unvented gas log sets and fireplaces.

Fits The Desa International Unvented Vent-Free Infrared Gas Wall Heater.

Fits Vanguard, Comfort Flame, Glo-Warm, Cozy Heat, Kozy World, Pro Com, Desa International and others Brand Parts.

silver and brown transmitter wires that.

The 120630-01 Pilot ODS assembly take the 120790-01 Dual Wire Thermocouple. The 120790-01 Thermocouple Dual Wire 33 Inch Length with silver and brown transmitter wires that fits the Desa International Unvented Vent-Free infrared gas wall heater.


Edward Dennis
2025-06-26 14:45:11
I used this in my natural gas, non-vented, logs. The pilot burner wouldn't keep a flame going so I used the thermocouple and igniter with my old pilot burner. This new pilot burner seemed to be sized for propane gas. I am a trained, licensed, gas appliance servicer and have the professional knowledge to make these adjustments. I personally recommend you hire a professional for these type repairs.
Mark Milholland
2025-06-16 17:58:59
Would not fit model as stated in the online description.
Ray
2025-03-27 11:34:39
First, mine is a Comfort Glow and my issue was the pilot was not igniting from the igniter and there was corrosion build up on the flu end after 23 yrs. Thus when I manually lit the pilot, it was half yellow with an up sweeping flame. If you have the old manual, you'll see this is not how it's supposed to be. It's supposed to be a straight, primarily blue flame across the thermocouple. Both pics are after install.I had the identical problem Jared did as I titled upon install of the new parts. Even though the provided orifice appeared to have a large enough hole, it did not provide proper fuel to the pilot. The pilot would come on only about an inch, then it would go out if I left it alone for a bit or when I tried to apply fuel. So as Jared said, simply swap it with the old orifice and the flame came on as it should and I now have properly functioning space heater to include pilot lighting.I only gave it a 4 star simply for the modification swap needed, other than that it would of gotten a 5.
Tommy
2025-03-12 13:28:14
So this is supposed to be the updated part number, according to DESA, for 110803-01. I own the ComfortGlow model CBN30T by DESA International. The old part is pictured attached to this review. The part looks different, but it does physically fit in my heater. The trouble is the pilot is weak. It actually gets snuffed out when after the heater cycles on, then cuts off when it reaches the desired temperature in the room. There is something wrong here. I wouldn't recommend this part.
jim groves
2025-03-08 10:47:41
I received this unit today and installed it which is a straight forward process. The pilot light on this unit did not allow enough gas thru to stay lit or heat the thermocouple enough to operate the main valve. I reused the old pilot because all I really needed was the thermocouple which so far appears to be working. I read other reviews about this item that had the same problem so there appears to be a quality assurance issue with the pilot light portion. So if you buy this unit and only need the ignitor and/or thermocouple you're in luck--I think-- but it's a hit or miss on the pilot light.I'm adding this after further study.I believe this unit has an orfice sized for propane rather than natural gas.Propane is delivered at a much higher pressure than natural gas thus requiring a smaller orfice.For natural gas, pilot orifices run from .014 to .026 and for LP from .006 to .013.Most natural gas pilots on heating using thermocouples are .018 or a tad larger that 1/64" (#77 drill bit). Quite a difference in orfice size hence the low flame.
B R Woods
2025-01-15 12:48:28
Part was an accurite fit and easy to install.
Jim
2024-12-03 14:41:06
Matches what I needed
Joseph wehunt
2024-11-14 15:28:06
Great prices an dame good about getting your things on time