Generator Interlock Kit for General Electric GE 150 and 200 Amp Panels with 1 1/4 Spacing, Generator to House Hookup Kit for GE Generator Interlock Kit & GE Interlock Kit 200 Amp

Free shipping on orders over $29.99

$9.99

$ 3 .99 $3.99

In Stock

About this item

  • 【Compatible Models】 Compatible with General Electric GE 150 and 200 Amp panels, the spacing between the main and the closest generator breaker is 1 1/4 inches
  • 【Enhanced Electrical Safety】 Ensure your electrical safety during power outages with our interlock kit. It allows for a seamless switch between AC and generator power, preventing the simultaneous opening of the main breaker and generator breaker, ensuring your safety during emergency generator use
  • 【Premium Quality】 Crafted from corrosion-resistant, high-hardness CNC machined aluminum alloys, and treated with surface anodization, our interlock kit offers superior heat and electrical insulation, providing you with a safe electrical experience
  • 【Easy Installation】We've made installation a breeze with the included 3/16" drill bit and sturdy steel components. Our comprehensive Installation guide ensures a hassle-free setup, even for those with limited electrical experience
  • 【Packages and Supports】 Your purchase includes everything you need - Interlock x1, safety labels x6, generator breaker retainer straps x2, a 3/16 drill bit x1, and an Installation guide x1. Plus, we're here to assist you with any questions or concerns during use; simply contact us for prompt support



Product Description

generator interlock kit
ge generator interlock kit
ge interlock kit 200 amp
generator interlock kit

Brett Mize
2025-09-05 14:18:11
Great product. Easy installation with instructions
Mike
2025-08-21 11:01:52
Installed on a 200 amp GE gold mark breaker box. Comes with the drill bit and all the hardware necessary. Plus it comes with all of the code required labeling. You do have to remove the front cover of the panel to install properly. Test fit everything and mark your holes accordingly. Then drill with the supplied drill bit. The mechanism slides easily with very little slop. When installed correctly, will prevent you from turning on the generator breaker while the main breaker is in the on position. For my panel, you must install the generator breaker in the top right position. Will not work in any other spot.
LITTLE E
2025-05-30 18:31:53
Works great. Thank you!
GPAJACK
2025-05-24 18:23:28
So when you backfeed a circuit breaker from a generator the back fed breaker needs to be fastened in place because if the breaker were to come loose the stab termains on the breaker would be energized. I would be curious if anyone has had an electrical inspection and passed using the provided zip ties. Typically the top breaker area has a point of attachement with a screw hole for a UL approved hold down kit.
William M.
2025-04-25 18:33:49
Installation was extremely easy and it’s a huge money saver over a Gen Tran Or transfer switch and subpanel. Would highly recommend.
jarhead
2025-03-29 18:30:45
A very easy device to install follow instructions and align parts per drawings. Took all of 15 minutes.Gives you piece of mind when using your generator no mistakes. Semperfi
Richard C.
2025-02-24 12:07:13
I was expecting some little piece of overpriced sheet metal just so I could meet code requirements. I was pleasantly suprised at the heft and quality of a simple little slider... and it even fits and works well.
jeremie keyworth
2025-02-04 13:13:28
To install!Safety first