NOYITO 10A 600W High Power MOS Trigger Switch Driver Module PWM Conditioning Electronic Switch Control Board FET MOS Trigger Switch Driver Module

Free shipping on orders over $29.99

$7.99

$ 3 .99 $3.99

In Stock

About this item

  • The module supports high level trigger, low level trigger, switch control, PWM control; dual MOS parallel active output, low internal resistance, strong current, strong power, continuous current at room temperature is 10A, 600W, satisfying most Equipment;
  • Working voltage input: DC 4V-60V; Easy to control high power equipment. (Please refer to the second picture on the left for the wiring diagram)
  • High-level trigger voltage range: DC3.0V-24V, trigger signal is 3.0V-24V, MOS tube is on; less than 0.6V, ie 0V-0.6V, MOS tube is off. The signal voltage cannot be 0.6V-3.0V, because the MOS tube is not fully open, the high power output will damage the MOS;
  • Low-level trigger voltage range: DC 0V-0.6V, trigger signal at 0V-0.6V, MOS transistor is on; above 3.0V, MOS transistor is off; signal voltage cannot be 0.6V-3.0V, because MOS tube is not complete Open circuit, high power output will damage MOS.
  • Output Capacity: DC 4V - 60V, continuous current 10A, room temperature, power 600W! The current can reach 15A under auxiliary cooling conditions.


Features:
The module supports high level trigger, low level trigger, switch control, PWM control;
It adopts imported dual MOS parallel active output, low internal resistance, strong current and strong power. The continuous current is 10A, 600W at room temperature, which is suitable for most equipments;
Easy to control high power equipment.

NOTE:
At the same time, there is only one signal to control the module, and two or more signals cannot be used to control the module;

Product parameters:
Working voltage: DC 4V - 60V;
Working temperature: -40- + 85 ° C;
Size: 3.4 * 1.7 * 1.2cm (LWH).

High Level trigger voltage range:
DC3.0V-24V, the trigger signal is at 3.0V-24V, and the MOS transistor is turned on;
Less than 0.6V, that is, 0V-0.6V, the MOS tube is turned off;
The signal voltage cannot be 0.6V-3.0V, because the MOS tube is not fully open, the high power output will burn MOS;

Low Level trigger voltage range:
DC 0V-0.6V, the trigger signal is at 0V-0.6V, and the MOS tube is turned on;
Above 3.0V, the MOS tube is turned off;
The signal voltage cannot be 0.6V-3.0V, because the MOS tube is not completely open, and the high power output will burn the MOS.

Trigger source:
High level trigger (DC3.0V - 24V), low level trigger (DC 0.0V-0.6V), switch control, can be connected to MCU IO port, PLC interface, DC power supply and other PWM signals, the range is 0 - 2.5KHZ.

Output capacity:
DC 4V - 60V, continuous current 10A, room temperature, power 600W! The current can reach 15A under auxiliary cooling conditions.

Package Included:
1pcs NOYITO 10A 600W High Power MOS Trigger Switch Driver Module


mkimid
2025-07-07 10:23:00
This is a ground switching type, and only allow. it means, it can not switching between two devices which is working in the same power source. such asA DEVICE - This board - B DEVICE(BATTERY>>>>>>>>>>>>>>>>>>)Even this board can disconnect the ground between A and B devices,If both devices are connected on the same power (battery), the ground has merged already.so, This board can not switching, and A/B device is connectedanyway, my board has been working some switches, and stop working. actually, it stay in ON status. and, I have gave-up the board. not sure what makes my board had dead.maybe I made a mistake or my board has an issue.One of great thing, the seller has contact me, They are watching customer’s feed back and try to fix any issue spontaneously. so, trustable seller.
Arthur Deco
2025-07-01 11:40:51
Arrived on time as described. The part works but the output must drive a load that is isolated from ground, like a motor with separate +and -. The output - can not be connected to ground. If you connect the output -(minus) to ground the +(positive) output will always be on. Their tech support was very good and got back to me right away to discuss and try to solve my issue.
mkimid
2025-04-26 11:00:04
This is a ground switching type, and only allow. it means, it can not switching between two devices which is working in the same power source. such asA DEVICE - This board - B DEVICE(BATTERY>>>>>>>>>>>>>>>>>>)Even this board can disconnect the ground between A and B devices,If both devices are connected on the same power (battery), the ground has merged already.so, This board can not switching, and A/B device is connectedanyway, my board has been working some switches, and stop working. actually, it stay in ON status. and, I have gave-up the board. not sure what makes my board had dead.maybe I made a mistake or my board has an issue.One of great thing, the seller has contact me, They are watching customer’s feed back and try to fix any issue spontaneously. so, trustable seller.
Arthur Deco
2025-01-02 11:57:23
Arrived on time as described. The part works but the output must drive a load that is isolated from ground, like a motor with separate +and -. The output - can not be connected to ground. If you connect the output -(minus) to ground the +(positive) output will always be on. Their tech support was very good and got back to me right away to discuss and try to solve my issue.