About this item

  • Practical split type design: the green terminal is connected to the device CT, the red and black wires are connected to measure the voltage, please do not connect incorrectly
  • Parameters information: current range is 0-200A; Voltage measurement error: 1% the multimeter can clearly display voltage and current at the same time, red for voltage, green for current
  • Adopting advanced technology: using first-class technology, 0.39 inch two-color highlight display; 200A measurement range is 0-200A, inner hole of transformer around 24 mm
  • Simple connection: the voltage ampere monitor is powered by the circuit under test, and the two-wire system does not need to connect an additional power source
  • Wide application: applied in distribution boxes, power distribution cabinets, voltage stabilizers, teaching appliances, small household distribution boxes



Feature:
The green terminal is connected to the transformer CT, and the red and black wires are connected to measure the voltage.
Closed back cover, discharge dustproof, safer to use.
The transformer is separated from the instrument and connected externally. The wire of the secondary end of the transformer can be lengthened to achieve the ideal installation position and be applied flexibly.
There are clear instructions on the back cover.
Specification:
Product gross weight: 0.104 kg
Measurement accuracy: 1%
Display mode: 0.39 inch LED display
Measurement rate: about 2 times per second
Power supply line, measuring line length: approx. 150 mm
Split transformer length: approx. 100 mm
Voltage range: 60-500V
Warm notes:
Please allow slight size error due to manual measurement.
The colors may exist slight difference due to different screen.


USA COMPUTER TECH
August 27, 2025
I've been using them for a while. They only light up dimly over 32v and get very bright at 127v AC. They seem to be accurate when testing the amperage against amp clamps. I don't know what will happen if I put 230v AC to them. The similar DC meters I tried all blew up after rectifying the voltage to DC.
Bob
August 6, 2025
They work great for monitoring single phase power. I use them to monitor incoming voltage and current on the 25 horsepower rotary phase converter I built.
King Julian
June 15, 2025
Installed on generator circuit inside house to monitor load as other reviewers have. The only thing that keeps this from being a 5 star product is the lack of wire. I think everyone would happily pay a couple dollars more for a better insulated wire that is a few feet long instead of 6 inches so we don't have to waste time extending wires. These all seem to be made the same way so maybe we're not using it as intended. Display is very easy to read in basement. Also, if they could make the housing the same dimensions as a GFCI outlet there would be a super easy off the shelf mounting plate option.
IanH
June 4, 2025
So far so good.2 gang deco plate needs to be enlarged about 1/8 inch wider.Length looks too long but just snapped in and holds fine. Will update when installed in garage and powered. Plate is flex poly not hard one. They broke when clamping in vice to dremel material away.
ccpanel
May 31, 2025
I have a good Klein digital clamp-on meter. One of the industry standards.This cheap chinese junk reads high or low amps by a factor of 4x at least.The voltage readout appears very accurateThat same wire was flowing ~10 amps and the chinese meter read ZERO.another time it was flowing 8 amps and the chinese meter read 11.nopehard pass
marc majlaton
April 23, 2025
Love these things. Easy to install.
Antonius
April 7, 2025
Bought a total of 6 so far. In the latest project on my Air Handler, came to the realization that the meters do not display by using a decimal point.Conclusion: The resolution is 1 Amp increments, and I don't read anything when the blower motor runs on the air handler. I expect to read at least 1 amp.On another side note, the power-up time is to be considered if you expect to capture in-rush current readings.
Michael M.
March 23, 2025
Using two of them (one on each hot wire) to keep an eye on my Bitcoin miners. They work good. I spent upwards of 30 minutes online researching other sellers on and off Amazon. These are the best.
Client d'
February 2, 2025
Cela nous permet de voir ce que nous consommons en électricité, et surtout avec la génératrice en cas de panne d'électricité.
Customer
January 27, 2025
not good only good for three month