Zachary Schreib
August 30, 2025
So easy to splice onto the plug in for the phased out, no longer made, Panasonic bathroom fan model no. FV-11VQ3. If you have even rudimentary wiring skills (stripping a wire, splicing a wire to another), this motor worked for me! I though I was up poop creek and would have to tear out the casing from the ceiling to replace the bathroom fan altogether. Well, through dilligent research, I happened upon this motor replacement, tried, it, spliced it, and VOILA!!!! It worked! Saved myself from ripping out and reinstalling a whole new unit! Hallelujah!
LJ S
August 24, 2025
My husband and I used this and successfully replaced the motor in a Panasonic Model No. FV 11VQ3 bathroom fan. The hardest part was disconnecting the wire assembly from the connector to take the fan out, which has nothing to do with this part. We did have to do a little bit of rewiring to put the original wire assembly onto this motor, but it worked! We also added one washer as a spacer just to make sure nothing was rubbing, but that is not necessary if you don't over-tighten the blower wheel to the motor.
Customer
August 4, 2025
Had to go from the 2 wire plug to the 3 wire from the old motor. After rewiring, works fine,
Cam-WA
July 22, 2025
I used this Panasonic replacement motor to repair my Panasonic model FB-08VQ3 bathroom fan. As others have pointed out, using this replacement motor for this model requires two modifications: (1) The wiring harness connector that comes with the newt motor does NOT match the one in this model fan; one needs to cut the connector off the new motor and splice in the connector from the old motor, and (2) On the shaft of the new motor washers need to be added to prevent the cage from rubbing on the housing.For me the hardest part was figuring out how to disassemble the old fan so I could take the innards out. This needs to be done to remove and replace the motor. Amazon does not permit external links in reviews, so I STRONGLY urge people to find and download the service manual for their model of Panasonic fan needing a new motor. Although the service manual was still somewhat confusing (because it has no pictures, only schematic diagrams) the additional information I gleaned there was enough to let me get the job done.Here is a description of the steps I took, in order:0. Close the toilet lid, close the sink stopper, and remove or cover any waste baskets or other objects into which a screw could possibly fall from the ceiling and get lost.1. Remove the grill by pulling down on two opposite edges, exposing two wire spring clips. Pinch each of the spring clips in turn between your thumb and forefinger as high up as possible so that the spring clips can be pulled away from the ceiling.2. You will now see a black plastic shroud covering the ceiling opening, except in the middle, where you can see a circular opening with the fan cage inside the opening. Open the electrical connector access door by pulling on what the service manual calls a “claw” (I don’t know why, it doesn’t look like a claw at all!). Behind this access door, you will see the electrical connector and you may also see a thumbscrew holding the shroud to the fan housing. In my case, the installer did not install the thumbscrew. The shroud is held in place by four Phillips head screws. These screws are deep inside four visible holes. In my case, even after removing the screws, it was not easy to pull the shroud down because the opening in the ceiling was just a little bit too small, and the shroud was stuck against the ceiling gypsum board. It took me a bit to work the shrouding out of the hole.3. The electrical connector clips in place. This connector can be a bit tricky to work loose. I knew that it was a matter of finding the right place to push so that the connector clip could clear the catch.4. There are three machine screws that hold the entire fan assembly in place. Remove these screws, being careful when removing the final screw to support the somewhat heavy fan assembly. In my case, the fan exhaust housing built into the fan assembly was stuck to the fan housing and I had to pull hard to get it loose.5. Take the fan assembly to a work bench or table. Turn the entire assembly upside down to reveal the motor capacitor box and the wires from the capacitor box to the motor and from the capacitor box to the wiring, harness connector (see photo). Remove the screws holding the capacitor box in place, the wiring harness strain relief, and the ground wire (if present). Also remove the six screws holding down the metal plate and lift off the metal plate (together with motor and fan cage) from the large plastic housing to which it was attached.6. Flip the motor unit over and remove the nut and lock washer that secure the fan cage to the motor shaft and remove the fan cage.7. Flip the motor unit over again and remove the four screws near the center holding the motor in place and remove the motor. It should now be possible to separate the motor along with the capacitor box, the wire connecting the capacitor box to the motor, and the wire harness with connector.8. Everything is now apart, and the rest of the process involves reversing the steps above, using the new motor in place of the old. BUT, most likely the new motor is different from the old motor in two important ways, as mentioned at the beginning of this long review. Since the wiring harness connectors are not likely to be the same, you need to remove the connector from both the old wire and the new wire and splice the old connector to the new wire. I did this a few inches away from the capacitor box after measuring to make sure that the length of the wiring harness with connector, after splicing, would be at least as long as it was with the old motor. The second difference is the need to place some washers on the new motor shaft before replacing the fan cage. For me this was trial and error, to discover how many washers I needed to put on the shaft so that (a) the fan cage didn’t rub on the housing and (b) the locknut and nut would fit on the end of the shaft.While not for the faint of heart, this process should be doable for anyone with reasonable DIY skills.
ak
July 14, 2025
As others have mentioned, this works as a replacement for Panasonic ceiling fans with blown motors; it requires some minimal splicing since the connectors are slightly different (you can use small gauge wire nuts or crimp kits - just match the black and white wires going to the connector).I'm still not sure what caused the old motor to fail in the first place - I suspect it's sensitive to voltage excursions from the line transformer circuit that feeds power to the house, combined with a lack of filtering or fusing.
Customer
July 14, 2025
Make sure to install same (inner) side of mounting plate and no washers unlike some other reviews say. Transfer old, 3 prong plug to the harness.Quiet, but time will tell longevity.
AB
June 30, 2025
I used this fan to repair a Panasonic FV-11VQ3 bathroom fan. The specific fan for that model has been discontinued everywhere I looked but some have pointed out this one will work.This fan is the same and will fit with two minor changes:1: Save the old fan to take the connector wire to swap. It's an easy swap out if you have a crimping tool and some connectors (white to white, black to black).2: The fan will rub on the housing so you'll need to place a couple of washers down first to raise it a bit when attaching the fan. This fan's output shaft stop is a bit closer to the body so a couple of washers will fix that right up. If you don't have some washers, just do what I did and place the locking washer on the bottom that should raise it the needed distance.After those two mods, it fired right up and is now working again.
Customer
June 23, 2025
It has no ground wire. The electric connector didn't match my equipment's.I simply removed it's wire connection, spliced it to the old one, extended the original ground, and installed the new motor without difficulty. In an aquard position I reinstalled the fan frame into the in ceiling mounting box. Overhead removal and remounting was the difficulty, not this product's fault.I would buy it again.
Ian RJ
June 23, 2025
Very easy to replace old motor with new.As mentioned you have to use old electrical wiring harness, but it’s not complicated.Speedy delivery.
Nolen
June 18, 2025
Change the plug with the old one, and it works.
Acer
June 16, 2025
Very expensive for a little motor. Put in my model and got the wrong end to plug in to existing Panasonic box.
Zachary Schreib
June 2, 2025
So easy to splice onto the plug in for the phased out, no longer made, Panasonic bathroom fan model no. FV-11VQ3. If you have even rudimentary wiring skills (stripping a wire, splicing a wire to another), this motor worked for me! I though I was up poop creek and would have to tear out the casing from the ceiling to replace the bathroom fan altogether. Well, through dilligent research, I happened upon this motor replacement, tried, it, spliced it, and VOILA!!!! It worked! Saved myself from ripping out and reinstalling a whole new unit! Hallelujah!
LJ S
May 27, 2025
My husband and I used this and successfully replaced the motor in a Panasonic Model No. FV 11VQ3 bathroom fan. The hardest part was disconnecting the wire assembly from the connector to take the fan out, which has nothing to do with this part. We did have to do a little bit of rewiring to put the original wire assembly onto this motor, but it worked! We also added one washer as a spacer just to make sure nothing was rubbing, but that is not necessary if you don't over-tighten the blower wheel to the motor.
Customer
May 12, 2025
Had to go from the 2 wire plug to the 3 wire from the old motor. After rewiring, works fine,
Cam-WA
April 29, 2025
I used this Panasonic replacement motor to repair my Panasonic model FB-08VQ3 bathroom fan. As others have pointed out, using this replacement motor for this model requires two modifications: (1) The wiring harness connector that comes with the newt motor does NOT match the one in this model fan; one needs to cut the connector off the new motor and splice in the connector from the old motor, and (2) On the shaft of the new motor washers need to be added to prevent the cage from rubbing on the housing.For me the hardest part was figuring out how to disassemble the old fan so I could take the innards out. This needs to be done to remove and replace the motor. Amazon does not permit external links in reviews, so I STRONGLY urge people to find and download the service manual for their model of Panasonic fan needing a new motor. Although the service manual was still somewhat confusing (because it has no pictures, only schematic diagrams) the additional information I gleaned there was enough to let me get the job done.Here is a description of the steps I took, in order:0. Close the toilet lid, close the sink stopper, and remove or cover any waste baskets or other objects into which a screw could possibly fall from the ceiling and get lost.1. Remove the grill by pulling down on two opposite edges, exposing two wire spring clips. Pinch each of the spring clips in turn between your thumb and forefinger as high up as possible so that the spring clips can be pulled away from the ceiling.2. You will now see a black plastic shroud covering the ceiling opening, except in the middle, where you can see a circular opening with the fan cage inside the opening. Open the electrical connector access door by pulling on what the service manual calls a “claw” (I don’t know why, it doesn’t look like a claw at all!). Behind this access door, you will see the electrical connector and you may also see a thumbscrew holding the shroud to the fan housing. In my case, the installer did not install the thumbscrew. The shroud is held in place by four Phillips head screws. These screws are deep inside four visible holes. In my case, even after removing the screws, it was not easy to pull the shroud down because the opening in the ceiling was just a little bit too small, and the shroud was stuck against the ceiling gypsum board. It took me a bit to work the shrouding out of the hole.3. The electrical connector clips in place. This connector can be a bit tricky to work loose. I knew that it was a matter of finding the right place to push so that the connector clip could clear the catch.4. There are three machine screws that hold the entire fan assembly in place. Remove these screws, being careful when removing the final screw to support the somewhat heavy fan assembly. In my case, the fan exhaust housing built into the fan assembly was stuck to the fan housing and I had to pull hard to get it loose.5. Take the fan assembly to a work bench or table. Turn the entire assembly upside down to reveal the motor capacitor box and the wires from the capacitor box to the motor and from the capacitor box to the wiring, harness connector (see photo). Remove the screws holding the capacitor box in place, the wiring harness strain relief, and the ground wire (if present). Also remove the six screws holding down the metal plate and lift off the metal plate (together with motor and fan cage) from the large plastic housing to which it was attached.6. Flip the motor unit over and remove the nut and lock washer that secure the fan cage to the motor shaft and remove the fan cage.7. Flip the motor unit over again and remove the four screws near the center holding the motor in place and remove the motor. It should now be possible to separate the motor along with the capacitor box, the wire connecting the capacitor box to the motor, and the wire harness with connector.8. Everything is now apart, and the rest of the process involves reversing the steps above, using the new motor in place of the old. BUT, most likely the new motor is different from the old motor in two important ways, as mentioned at the beginning of this long review. Since the wiring harness connectors are not likely to be the same, you need to remove the connector from both the old wire and the new wire and splice the old connector to the new wire. I did this a few inches away from the capacitor box after measuring to make sure that the length of the wiring harness with connector, after splicing, would be at least as long as it was with the old motor. The second difference is the need to place some washers on the new motor shaft before replacing the fan cage. For me this was trial and error, to discover how many washers I needed to put on the shaft so that (a) the fan cage didn’t rub on the housing and (b) the locknut and nut would fit on the end of the shaft.While not for the faint of heart, this process should be doable for anyone with reasonable DIY skills.
ak
April 24, 2025
As others have mentioned, this works as a replacement for Panasonic ceiling fans with blown motors; it requires some minimal splicing since the connectors are slightly different (you can use small gauge wire nuts or crimp kits - just match the black and white wires going to the connector).I'm still not sure what caused the old motor to fail in the first place - I suspect it's sensitive to voltage excursions from the line transformer circuit that feeds power to the house, combined with a lack of filtering or fusing.
Customer
April 15, 2025
Make sure to install same (inner) side of mounting plate and no washers unlike some other reviews say. Transfer old, 3 prong plug to the harness.Quiet, but time will tell longevity.
AB
February 21, 2025
I used this fan to repair a Panasonic FV-11VQ3 bathroom fan. The specific fan for that model has been discontinued everywhere I looked but some have pointed out this one will work.This fan is the same and will fit with two minor changes:1: Save the old fan to take the connector wire to swap. It's an easy swap out if you have a crimping tool and some connectors (white to white, black to black).2: The fan will rub on the housing so you'll need to place a couple of washers down first to raise it a bit when attaching the fan. This fan's output shaft stop is a bit closer to the body so a couple of washers will fix that right up. If you don't have some washers, just do what I did and place the locking washer on the bottom that should raise it the needed distance.After those two mods, it fired right up and is now working again.
Customer
February 13, 2025
It has no ground wire. The electric connector didn't match my equipment's.I simply removed it's wire connection, spliced it to the old one, extended the original ground, and installed the new motor without difficulty. In an aquard position I reinstalled the fan frame into the in ceiling mounting box. Overhead removal and remounting was the difficulty, not this product's fault.I would buy it again.
Ian RJ
February 12, 2025
Very easy to replace old motor with new.As mentioned you have to use old electrical wiring harness, but it’s not complicated.Speedy delivery.
Nolen
February 7, 2025
Change the plug with the old one, and it works.
Acer
February 3, 2025
Very expensive for a little motor. Put in my model and got the wrong end to plug in to existing Panasonic box.